arXiv:2611.33194v1 Announce Type: new Abstract: Phase unwrapping underlies radar interferometry, magnetic resonance imaging and optical metrology. When an image is too large or too difficult to unwrap in one piece, many methods cut it into units, unwrap each unit, and merge the results. To our knowledge, no systematic review had brought these partitioned methods together. This review gathers them, for two-dimensional images and three-dimensional volumes. It describes how the units are built: fixed tiles, adaptive tiles, regions computed from the data, or pieces imposed by the acquisition, such as subapertures, slices and scenes. It then classifies how the units are merged, in four classes: after each unit is unwrapped, through one integer per jump-free region, during the solve, or through an external reference. Three findings stand out: building the units and merging them are two separate decisions; the merging rule decides whether the merged phase stays congruent with the measured one; and most tests change both decisions at once, so few results show which one helps. We state what a study can report to support a claim on memory, speed or accuracy. Our aim is to document the methods, not to rank them. Following PRISMA 2020, four bibliographic databases (OpenAlex, IEEE Xplore, Web of Science and Scopus), searched on 1 October 2026, returned 1,800 records. After removing duplicates, screening titles and abstracts, adding a citation search and reading 298 full texts, we included 149 studies, published from 1987 to 2026. The review was not registered and received no specific funding.