arXiv:2611.33786v1 Announce Type: new Abstract: Relating tongue motion measured with dynamic MRI to the speech it produces could inform rehabilitation after glossectomy. Prior studies have translated cine or tagged MRI into log-mel spectrograms and used the two-dimensional Pearson correlation between predicted and recorded spectrograms (Corr2D) to quantify the acoustic information captured by each imaging modality. However, Corr2D has not been calibrated against MRI-free predictors that preserve basic acoustic structure. Our contribution is an evaluation framework for speech synthesis from cine MRI, tagged MRI and their combination; the synthesis network is held fixed. On identical leave-one-subject-out folds, we compare four trained input configurations with two MRI-free controls: a static mean-spectrum baseline and a time-aligned cohort template. Across 44 subjects (18 after glossectomy) producing two utterances, the cohort template, which never sees an MRI, reached a Corr2D of 0.745 and 0.664. The static baseline, which contains no timing, reached 87 to 89% of that score. No trained configuration outperformed the template on Corr2D, a cepstral distance or ESTOI; seven of the eight fell significantly short on Corr2D. For cine MRI this held across three positional encodings, an encoder temporal-attention module and a training objective matched to the metric. Cine and tagged MRI differed consistently within subjects, although the direction depended on the metric. Absolute Corr2D alone therefore does not show that a model recovers acoustics from the MRI. The two controls are a reusable method: any study can compute them from its own training recordings, so a model's margin over them measures what its images contribute.