AI & ML
Reliability assessment and multicenter clinical application of magnetic resonance methods for knee cartilage quantification
arXiv eess.IV0 views
arXiv:2609.08081v2 Announce Type: replace Abstract: Background: This study evaluated interreader agreement and longitudinal performance of MRI methods for knee cartilage volume, thickness, and defect-area quantification. Methods: AI-presegmented masks from 1,189 phase III examinations underwent independent correction by two readers and adjudication. Cartilage volume, three-dimensional ray-tracing thickness (3D-RT), and ray-based defect area (3D-RBA), defined by a 1.5-mm thickness threshold, were calculated. Agreement was assessed using segmentation metrics, intraclass correlation coefficients (ICCs), repeated-measures Bland-Altman analysis, and minimal detectable change at 95% confidence (MDC95). The 3D-RBA framework was evaluated in 120 digital-phantom experiments from 40 participants. Longitudinal analyses included 374 participants, alternative-method comparisons included 65, and retrospective phase II analysis included 24 participants with four visits. Results: Overall AI-to-adjudicated-mask Dice was 0.964 +/- 0.029. Interreader ICCs for volume, thickness, and defect area were 0.956, 0.904, and 0.932; corresponding MDC95 values were 1,596.9 mm^3, 0.227 mm, and 147.4 mm^2. Geometric mean absolute percentage error for defect area was 5.62%, with spatial Dice of 0.961. In 374 participants, volume changes correlated positively with thickness changes (rho=0.431) and negatively with defect-area changes (rho=-0.221). Within-participant phase II correlations followed the same directions in both groups. Conclusions: The workflow demonstrated good interreader agreement. Controlled geometric results and longitudinal associations supported the feasibility of threshold-based defect-area estimation. Volume, thickness, and defect area provide complementary measures of cartilage structure.
Source:https://arxiv.org/abs/2609.08081PreviousSCI-Mamba: Unsupervised Learning based Low-Light Image Enhancement for Non-Cooperative SpacecraftNextThe segmentation ceiling: why explicit left-ventricular masks do not improve learned ejection-fraction regression
Related posts
Cilium 1.20.0 Requires BTF Flag in Linux Kernel, Raspberry Pi OS Kernel Incompatible Without It
0dev.to
YC Labs and Olam Labs ran 50 AI agents in a Minecraft civilization experiment
0dev.to
Lavoro su piattaforma e algoritmi: cosa cambia con la direttiva europea per chi progetta il software
0dev.to
LifeVal Benchmark Targets Everyday Personal Assistant Tasks Shaped by ChatGPT User Feedback
0dev.to
Oracle files to sell $20B in new stock, bonds to finance AI buildout
0Hacker News
7.9% to 48.1%: LLM rewrote Qwen weights, no training
0dev.to