Blower listings can mix horsepower, kilowatts, CFM, cubic metres per hour and battery capacity without showing how the values relate. A spreadsheet is useful, but a short script is faster when you are screening multiple quotations. The checks below turn obvious inconsistencies into concrete questions for a supplier. They do not replace testing or documentary review.

Two listings make good examples. The 40V cordless leaf blower listing lists USD 56.00–60.50 per piece with an MOQ of 2 pieces at the time of writing. The CU-3HP-F3 inflatable blower listing lists USD 84.80–124.80 per piece with an MOQ of 1 piece. Those are listed prices, not quotations, and they can change.

What the script checks

The first check compares horsepower with kilowatts using 1 HP = 0.7457 kW. The second compares a CFM figure with its advertised cubic-metre figure. I use 1 CFM = 1.699 m³/h, so the result is a consistency check, not a measurement.

The current calculation is deliberately simple:

I >= P / V

Here, P is the listed rated power in watts and V is the buyer's mains voltage. This is a lower bound under simplified assumptions. Motor losses and power factor can make the actual current higher. If the listed power is shaft output rather than electrical input, the input power will also be higher. Ask for input power and full-load current at each offered voltage.

The battery calculation multiplies nominal voltage by amp-hours, divides by watts and converts hours to minutes:

runtime <= (V × Ah) / W × 60

This is an upper bound, not a runtime forecast. It omits battery-management-system cutoff, motor losses and changes in load. Use it to spot impossible claims and to frame questions, not to promise working time.

The script

The following dependency-free script embeds the specification values used for these two examples:

#!/usr/bin/env python3 from dataclasses import dataclass HP_TO_KW = 0.7457 CFM_TO_M3H = 1.699 @dataclass(frozen=True) class AcModel: hp: float kw: float cfm: float listed_m3h: float AC_MODELS = [ AcModel(1.5, 1.12, 2460, 4179.56), AcModel(2, 1.49, 2580, 4383.45), AcModel(3, 2.24, 2890, 4910.14), ] def current_bound(kw, mains_v): return (kw * 1000) / mains_v def runtime_upper_bound(v, ah, watts): return (v * ah / watts) * 60 def main(): print("AC model checks") for model in AC_MODELS: converted = model.cfm * CFM_TO_M3H print(f"{model.hp:g} HP | listed {model.kw:.2f} kW | " f"HP conversion: {model.hp * HP_TO_KW:.3f} kW") print(f" flow conversion: {converted:.2f} m3/h | " f"listed: {model.listed_m3h:.2f} | " f"delta: {converted - model.listed_m3h:+.2f}") for mains_v in (110, 220): amps = current_bound(model.kw, mains_v) print(f" at {mains_v} V, current >= {amps:.2f} A") print("Cordless runtime upper bounds") for ah in (5.0, 7.5): energy_wh = 40 * ah minutes = runtime_upper_bound(40, ah, 575) print(f" {energy_wh:.0f} Wh / 575 W -> {minutes:.1f} min") if __name__ == "__main__": main() 

Run it with python3 spec_sanity.py. The point is not the formatting of its output; it is to force the units into the same calculation and expose missing inputs.

What the cordless listing reveals

In the 40V cordless listing, model CY-1-D, the page lists both “Air watts: 575W” and “Power: 575W.” It does not make clear whether 575 W is electrical input or an air-power metric. That distinction matters for runtime. The listing gives battery capacities of 5.0 Ah and 7.5 Ah, or 5000 mAh and 7500 mAh, but no runtime.

At 40 V, those packs contain 200 Wh and 300 Wh: 40 × 5.0 and 40 × 7.5. If 575 W were electrical input at full power, the simple upper bounds would be about 20.9 minutes for 5.0 Ah and 31.3 minutes for 7.5 Ah. Those are my calculations, not supplier figures, and both are optimistic for the reasons above.

The page also says “Max Air Flow: 600CFM” but gives no m³/h figure, air speed or test method. Separately, the motor field lists both brushless and brushed options. Ask which motor the quoted configuration has. The brand field says “Aboite,” while the supplier name is Zhongshan Aobaite Metal Industrial Co,. Ltd.; ask which name appears on the product and label. The weight field contains several values without labels explaining them, so request net and gross carton weights for the exact configuration.

Useful questions before a purchase order:

  • Is 575 W the electrical input, shaft power or an air-power measure?
  • What runtime was measured, with which battery, load and cutoff voltage?
  • Which motor type is included in the quotation?
  • What air speed and test method support the 600 CFM figure?
  • Which weight values are net and gross, and do they include the battery?
  • Which brand name will appear on the product and label?

What the AC listing reveals

The CU-3HP-F3 listing's rated-power table says 1.5 HP (1.12 kW), 2 HP (1.49 kW) and 3 HP (2.24 kW). At the stated HP-to-kW conversion, the kilowatt values agree to the shown rounding. The title's “1 HP” is therefore worth clarifying because the table starts at 1.5 HP.

The CFM and m³/h pairs also agree within small rounding differences. One row pairs 2460 CFM with 4179.56 m³/h; another pairs 2580 CFM with 4383.45 m³/h; the third pairs 2890 CFM with 4910.14 m³/h. However, the separate “Speed” field gives 4100, 4300 and 4800 m³/h, while the second “Max airflow” field says 4100–4800 m³/h. The highest value differs from 4910.14 m³/h, and “Speed” is being used as an airflow field. Ask which figures apply to each quoted version and how they were measured.

For the 3 HP, 2.24 kW row, the script's lower-bound current is 20.36 A at 110 V and 10.18 A at 220 V. These are arithmetic results from P / V, not measured or nameplate current. The listing offers 110–120 V / 60 Hz and 220–240 V / 50 Hz, so request full-load current separately for the exact voltage and frequency being purchased.

The listing also gives a max-pressure range of 1000–2200 Pa without mapping each value to a power version. It says package size differs by wattage without providing carton dimensions or weights. Its certification field states “CE/U.L/FCC/TUV/GS/CA”; treat that as a supplier statement, request copies, and check that each document covers the exact model, voltage and intended market with a qualified advisor or competent authority.

Before ordering, ask:

  • Is the quoted unit 1.5 HP or a different table version, despite the title?
  • Which airflow value applies: the CFM conversion, the “Speed” field or the range?
  • What test conditions and method produced airflow and pressure?
  • What is the input power and full-load current at the exact voltage?
  • What are the carton dimensions and gross weight for that version?
  • Can the supplier provide certification documents covering the quoted model?

The script will not settle those points. It makes the questions concrete while the quotation is still easy to change.

Disclosure: this article is published by GLO Suppliers, the B2B marketplace where the listings discussed here appear. Specifications are quoted from the listings as published; confirm everything with the supplier before ordering.